Ion beam therapy (IBT) is a steadily growing field of radiotherapy, with now around 30 centres worldwide offering therapy with mainly proton and/or carbon ion beams. One of the current drawbacks with IBT is the cost of the accelerator required to produce fast ions, and alternative means of ion acceleration are being sought which could rival the beam characteristics of modern cyclotrons and synchrotrons. One highly active area of research is acceleration in plasmas created by intense, short pulsed, high-powered lasers [1].
The TARANIS laser at Queens University Belfast was used to accelerate protons from a 10 μm Au foil target via target normal sheath acceleration (TNSA) [2]. A stack of dose-to-water calibrated GafChromic films consisting of HD810 and EBT was placed 2.5 cm from the target to measure dose-to-water versus depth. Currently the TARANIS setup is capable of accelerating protons up to approximately 12 MeV.
The Monte Carlo code FLUKA was used to produce an array of Bragg curves in water for initial proton energies between 0-15 MeV, combined with a previously determined GafChromic film proton response function [3]. These Bragg curves were iteratively summed with different weightings until they agreed with proton depth-dose measurements, resulting in a histogram-like measurement of proton energy spectrum. To account for the energy loss due to a 20 μm Al filter in front of the film stack, FLUKA was used to create a matrix containing the energy loss transformations for each individual energy bin. Multiplication by the pseudo-inverse of this matrix results in "up-shifting" protons to higher energies. A simple thermal expansion model which describes energy spectra resulting from TNSA was fitted, giving a proton temperature (kBT) of 3.97 MeV and total number of protons (N0) of 5.76·1013 cm-2 which is comparable to GafChromic film measurements made elsewhere using similar laser accelerator apparatus. This work demonstrates the successful application of the dose-to-water formalism in dosimetry of laser accelerated ion beams, and also leads to a more accurate estimate of the proton spectrum and total proton yield than has been previously obtained.
This work was supported by EPSRC (grant number EP/E035728/1) and the LIBRA consortium.
References
- 1.
- Borghesi M, et al. Multi-MeV proton source investigations in ultraintense laser-foil interactions. Phys Rev Let 2004;92:055003.
- 2.
- Hatchett SP, et al. Electron, photon, and ion beams from the relativistic interaction of Petawatt laser pulses with solid targets. Plasma Phys. 2004;7:2076.
- 3.