Microvasculatory reaction of skeletal muscle to Ti-15Mo in comparison to Ti-6Al-4V and Ti-6Al-7Nb
Suche in Medline nach
Autoren
Veröffentlicht: | 28. September 2006 |
---|
Gliederung
Text
Introduction: Beta-titanium alloys such as Ti-15Mo are increasingly utilized for orthopaedic implant applications because of their excellent corrosion resistance and low elastic modulus. Particularly in osteosynthesis, where the biomaterial stands in direct contact to soft tissue, undesirable biologic reactions may have severe consequences especially in the vulnerable state of trauma and added iatrogenic damage to the microvascular system. In a comparative study we therefore assessed in vivo nutritive perfusion and leukocytic response of striated muscle to the biomaterials Ti-15Mo, Ti-6Al-4V and Ti-6Al-7Nb, thereby drawing conclusions on their short term inflammatory potential.
Methods: 4 mm2 large samples with a thickness of 0.5 mm of either Ti-15Mo (ASTM F 2066), Ti-6Al-4V (ASTM F 136) and Ti-6Al-7Nb (ASTM F 1295)were used. In 28 hamsters, utilizing the dorsal skinfold chamber preparation and intravital microscopy, we quantified primary and secondary leukocyte-endothelial cell interaction, leukocyte extravasation, microvascular diameter change and capillary perfusion in collecting and postcapillary venules of skeletal muscle.
Results: We could not demonstrate any significant discrepancies between the three alloys. All metals induced an initial moderate inflammatory response in skeletal muscle microcirculation. While recuperation of animals treated with Ti-15Mo and Ti-6Al-7Nb was prompt, we documented a slightly more sluggish recovery of Ti-6Al-4V treated animals. A gross toxicity was not observed for any of the alloys.
Conclusion: Conclusively, Ti-15Mo, Ti-6Al-4V and Ti-6Al-7Nb induce an only transient inflammatory answer of the striated muscle microvascular system. Our results indicate that on the microvascular level the tested bulk Ti-alloys do not cause enduring biologic impairment in muscle.